Product

12.1″ Utouch Patient Monitor S9000C

12.1" color TFT touch screenWindows style; Multi-channel display; Big font interface; ST and arrhythmia analysis; Drug dose calculation and titration table; OxyCRG dynamic view displayRespiration monitor; Carton size: 42cm*26cm*37cm; NW: 3.5kgs; CE and ISO

12.1" color TFT touch screen

Windows style, Multi-channel display

Big font interface

ST and arrhythmia analysis

Drug dose calculation and titration table

OxyCRG dynamic view display

Respiration monitoring with apnea alarms

Alarm review, arrhythmia review

Patient info. Input

Anti-defibrillation design

NIBP over pressure protection

Plug-in rechargeable battery, AC/DC available.

Supporting wire or wireless network.

Adopting Aiah(TM) ECG technology, anti-interference, be able to collect the weak ECG signal away from interference.

Adopting Surepeb(TM) NIBP technology, accurate measurement to high blood pressure patient and low blood pressure patient.

 

SP02

Nellcor(TM)  OxiMax(TM) is the world leading SpO2 technology

Nellcor(TM)  OxiMax(TM) delivers excellent performance,

even in the difficult monitoring conditions of low perfusion and signal interference, including patient motion.

 

ETCO2

Collaborate with Respironics, Plug and Play EtCO2 monitoring.

CAPNOSTAT mainstream sensor for optimal performance in monitoring intubated patient. Small, durable and lightweight mainstream sensor provides accurate

and reliable monitoring for all intubated patients from neonates to adults. Loflo sidestream sensor for monitoting non-intubated patient.

Flexible, compact CO2 sensor provides consistent and reliable monitoring of adult, pediatric and neonatal patients.

 

Multi Mounting Solutions

ECG

Lead Mode                          5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection                     I, II, III, avR, avL, avF, V

Wave form                          2 ch

Lead mode                          3 Leads ( R, L, F or RA, LA, LL)

Lead selection                     I, II, III,

Wavef orm                          1 ch

Gain                               2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto

HR and Alarm Range                 Adult    15 ~ 300 bpm

                                   Neo/Ped    15 ~ 350 bpm

Accuracy                           ±1% or±1bpm, which is greater

Resolution                         1 bpm

Sensitivity                        > 200 (uVp-p)

Differential Input Impedance       > 5 MΩ

CMRR                   Monitor > 105 dB

                                   Operation > 105 dB

                                   Diagnosis > 85 dB

Electrode offset potential         ±300mV

Leakage Current                    < 10 uA

Baseline Recovery                  < 3 S After Defi.

ECG Signal Range                   ±8 m V ( Vp-p )

Bandwidth                           Surgery    1 ~ 20 Hz

                                    Monitor     0.5 ~ 40 Hz

                                    Diagnostic  0.05 ~ 130 Hz

Calibration Signal                  1 (mVp-p),  Accuracy:5%

ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV

 

ARR Detecting                       Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,

                                          PNP, PNC,Alarm Available,Review Available

 

Respiration

Method                            Impedance between R-F(RA-LL)

Differential Input Impedance       > 2.5 MΩ

Measuring Impedance Range          0.3~3 Ω

Base line Impedance Range          200~4 KΩ

Bandwidth                          0.1~2.5Hz

Resp. Rate                         Measuring and Alarm Range

                                    Adult 0 ~ 120 Brpm

                                    Neo/Ped 0 ~ 150 Brpm

                                    Resolution 1 Brpm

                                    Accuracy ±2 Brpm

Apnea Alarm                        10 ~ 40 S


NIBP

Method                            Oscillometric

Mode                              Manual, Auto, STAT                        

Measuring Interval in AUTO Mode   1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)

Measuring Period in STAT Mode     5 Min

Pulse Rate Range           40 ~ 240 bpm

Alarm Type                  SYS, DIA, MEAN

Measuring and alarm range        Adult Mode

                                    SYS 40 ~ 270 mmHg

                                    DIA 10 ~ 215 mmHg

                                    MEAN 20 ~ 235 mmHg

                                Pediatric Mode

                                    SYS 40 ~ 200 mmHg

                                    DIA 10 ~ 150 mmHg

                                    MEAN 20 ~ 165 mmHg

                                Neonatal Mode

                                    SYS 40 ~ 135 mmHg

                                    DIA 10 ~ 100 mmHg

                                    MEAN 20 ~ 110 mmHg

Resolution                      1mmHg

Accuracy                        Maximum Mean error ±5mmHg

                                Maximum Standard deviation ±8mmHg

Overpressure Protection          Adult Mode 297±3 mmHg

                                 Pediatric Mode 240±3 mmHg

                                 Neonatal Mode 147±3 mmHg

SpO2

Measuring Range                  0 ~ 100 %

Alarm Range                      0 ~ 100 %

Resolution                       1 %

Accuracy                         70% ~ 100%  2 %

                                 0%  ~  69% unspecified

Actualization intervalabout      1 Sec.

Alarm Delay                      10 Sec.

Pulse Rate                       Measuring and Alarm Range 20~300 bpm

                                 Resolution       1bpm

                                 Accuracy ±3bpm                         

TEMP

Channe                          2

Measuring and Alarm Range 0 ~ 50 ℃

Resolution                      0.1 ℃

Accuracy                 ±0.2 ℃

Actualization intervalabout     1 Sec.

Average Time Constant           < 10 Sec.

IBP

Label                           ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range       ART 0 ~ 300 mmHg

                                PA -6 ~ 120 mmHg

                                CVP/RAP/LAP/ICP-10 ~ 40 mmHg

                                P1 / P2-10 ~ 300 mmHg

Press Sensor                    Sensitivity 5  uV/V/mmHg

                                Impedance 300-3000Ω

Resolution                      1 mmHg

Accuracy                        ±2% or 1mmHg which is greater

Actualization interval         about 1 secretary

 

Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature

Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder

Click to Contact